TO 10 Contrast Detail PhantomA contrast detail phantom for fluoroscopy systems.

These test objects are designed for quick quantitative assessments of image quality. The results can be plotted on a Threshold Detection Index Curve. TO 10 is intended for use with Fluoroscopy systems.

PDC

Quick, Easy Calibration of DAP (KAP) & Patient Dose Systems.

What’s it all about? Patient Dose Calibrator

Traceable Measurements

The PDC is a reference class instrument for “field calibration” of patient dose measurement and control systems thus ensuring the validity of inter-institution patient dose comparisons.

Flexible and Convenient

Use the PDC with a phantom to simulate patient imaging conditions including scattered radiation or mount the PDC on its support stand to measure air Kerma.

Simple to Use

The PDC displays DAP (KAP) and dose rate during an exposure then automatically switches to display accumulated DAP (KAP) and dose on exposure completion.

Dependable

A tough ABS plastic housing protects the ion chambers and electronics that incorporate several patented features to ensure long-term stability.

The energy dependence of the response of a patient dose calibrator.
Assessment Of An Instrument For Calibrating,Dose Area Product (DAP) Meters

 

Product Brochure

DAPcheck Plus

DAPcheck Plus DAP Check Light Field Congruence

Verify X-ray DAP & Light Field Congruence.

Traceable Measurements

The DAPcheck Plus is a reference class instrument for “field calibration” of patient dose measurement and control systems thus ensuring the validity of inter-institution patient dose comparisons.

Fast and Accurate

Utilizing the high-speed digitization of the Accu-Gold digitizer, the DAPcheck Plus displays DAP and DAP Rate of accumulated DAP on exposure completion.

Dependable

A tough ABS plastic housing protects the ion chambers and electronics that incorporate several patented features to ensure long-term stability.

Plus

Also provides X-ray to light field congruence.

 

Specification Sheet

TOR DEN digital

Leeds Test Objects′ TOR DEN Digital phantom is designed to be used to check the image quality performance of digital dental x-ray systems including intra-oral, panoramic and cephalometric units. These tests should be carried out at acceptance to establish a baseline, and on a routine basis, keeping an on-going record of the test results, which will indicate any deterioration in performance.

TOR DEN digital is used for units with digital image acquisition, and enables the following tests to be made:

  • Limiting Spatial Resolution
  • Low Contrast Resolution
  • Image Receptor Dose
  • Radiation Field Alignment ~ for Panoramic and Cephalometric tests only
  • Image Quality Homogeneity ~ for Panoramic and Cephalometric tests only

The phantom is available as either;

  • INTRA-ORAL : Phantom and protective case
  • INTRA-ORAL + OPG : Phantom, protective case, tripod and alignment jig.

AGLS

AGLS Luminance Illuminance In the diagnostic imaging environment, the Radcal lightmeter measures the luminance level (brightness) and uniformity of back-lighted display screens, plus the illuminance level of the ambient light incident upon the screen surface. The meter displays photometric parameters in metric (SI) units.

TYPE
Portable, hand-held lightmeter for the measurement of display surface luminance and ambient light cosine-corrected illuminance.

MEASURING CAPABILITY
Measures luminance level in candela per square meter (nits) units and ambient light level in lux units.

LIGHT SENSOR
The base unit of the light meter contains a silicon photo-diode that can be exposed to ambient light through an optical filter, which very accurately simulates the spectral response of the human eye’s photopic response, in order to measure illuminance in lux units. A Luminance adapter can be attached to the Illuminance base sensor above the photo-diode for the measurement of luminance in cd/m² through an aperture with a 10-mm diameter. Accu-Gold automatically detects the presence or absence of the Luminance adapter and selects the appropriate units.

90M9

90m9 Invasive Anode Current Sensor mA mAsThe 90M9-AG and 90M9 are invasive sensors.

The mAs sensor connects to models Accu-Gold / Rapid-Gold / Accu-Pro / Accu-kV and to the X-ray generator with safety-shrouded banana jacks. The jacks are not polarity sensitive. It is intended to be inserted in series with the X-ray generator return.

The Accu-Pro and Accu-kV require a kV sensor in-beam as a trigger source.

The 90M9-AG and 90M9 measure DC current. When measuring AC current, we recommend using Model 90M9-BR. Click on the “Sensors and Accessories” tab above for details

90M10

90M10 Non-Invasive Anode Current Sensor mA mAsThe 90M10-AG and 90M10 are Non-Invasive Clamp on Sensors.

The mAs sensor connects to models Accu-Gold / Rapid-Gold / Accu-Pro / Accu-kV and couples to the X-ray generator by clamping to the X-ray anode HV cable (clamps up to 23mm diameter).

The Accu-Pro and Accu-kV require a kV sensor in-beam as a trigger source.

To measure Anode current, clamp on the anode cable with the arrow on the clamp pointing towards the X-ray tube. For best results, do not move clamp before and during a measurement or place next to the X-ray tube.

AGMS-D+

AGMS-D+ Solid State kV/Dose MultisensorThe AGMS-D+ is a Solid State kV/Dose Multisensor for Diagnostic Range Measurements.

A small Solid State multi-parameter sensor used for single exposure and fluoroscopy. It measures dose, dose-rate, time, kVp with FFT analysis, HVL, and beam filtration. It features correction of dose for beam quality.